Measuring Alignment Telescope PPS-11
PPS-11 Is designed for measurement of non-straightlinearity, misalignment, non-perpendicularity, out-of-levelness of plane surfaces and aperture misalignment on objects of up to 30 m in length.
Specifications:
Distance measurement renge during target sighting, m |
0,5 - 30 |
Telescope magnification for infinity focusing 26 |
26 |
Indicating device measurement renge, mm |
0 - 2 |
Scale interval of indicating device, mm |
0,01 |
Misalignment of line of sight and external cylinder |
45 |
Telescope resolution limit |
6,5" |
Adjustment renge of telescope positioning on the mount |
|
linear, mm: |
|
horizontal |
12 |
vertical |
7 |
engular, °: |
|
horizontal |
4° |
vertical |
2,5° |
around optical axis |
6° |
Measurement limits for target with square figures, mm: |
|
horizontal |
0 - 36 |
vertical |
0 - 36 |
Measurement limits for target with concentric circles , mm: |
±26 |
Measurement limits for target with concentric circles of 40 mm in diameter , mm: |
±13 |
Telescope bore diameter, mm |
64 |
Telescope measurement error tolerance, mm: |
|
for focusing on the target with concentric circles*
|
± (0,02+0,005 L) |
for focusing on the target with square figures *
|
± (0,02+0,007 L) |
Overall dimensions, mm, max.: |
|
of telescope |
525×130×135 |
of mount |
300×260×200 |
Mass, kg, max.: |
|
of telescope |
6 |
of mount |
10 |
*) L is a distance (m) from the alignment telescope butt to the object of sighting
|